auto up initialization procedure
just in case this happens to you while you are installing door speakers or doing anything inside the door. if you put everything back together and notice your auto up feature isnt working on the window and the window just rolls down everytime you open the door (without going back up after closing) do this.
INITIALIZATION PROCEDURE
1. Disconnect battery negative terminal or power window switch connector. Reconnect it after a minute or
more.
2. Door switch is OFF (close).
3. Turn ignition switch ON.
4. Operate power window switch to fully open the window. (This operation is unnecessary if the window is
already fully open.)
5. Continue pulling the power window switch AUTO-UP. Even after glass stops at the fully closed position,
keep pulling the switch for 3 seconds or more.
6. Initializing procedure is completed.
7. Inspect anti-pinch function.
CAUTION:
When initialization is not complete, power window UP does not operate while door is open.
Last edited by 510z; 05-05-2009 at 02:00 PM.
Reason: taken from service manual
|