Quote:
Originally Posted by bunk
...I dont know how I would test the module under load as the connector from the harness is enclosed. ...
|
Assuming the 50W mentioned above is what the module pulls under full load, you don't have the have the module connected to perform the test. Poke a nail, stiff wire, or similar conductor into the harness connector pin and attach light to it. Ground the other side of the light.
50W @ 12V = 4.2A, so it's not going to be pulling a lot of current but you might want to put a 10A (or 6A slo-blo)* fuse in series with the light - just to be on the safe side.
*Incandescent bulbs have a high inrush current so you need a "big" fuse or one that will survive the initial current draw.